Skip to product information
1 of 1

Siemens

RDF510 Flush mount room thermostat for 2-pipe FCU with on/off output, fit for square conduit boxes

RDF510 Flush mount room thermostat for 2-pipe FCU with on/off output, fit for square conduit boxes

SKU:RDF510/BP

393 in stock

Regular price RM254.00
Regular price RM212.00 Sale price RM254.00
Sold out
Shipping calculated at checkout.

Voltage AC/DC
Output
User Interface

 

Flush-mount thermostat with LCD display for fan coil units
  • Output for on/off valve actuator, 3-wire on/off valve
  • 3-speed fan control: Automatic or manual
  • Manual heating / cooling changeover or continuous Cooling only / Heating only
  • Operation modes: Comfort and Protection
  • Adjustable commissioning and control parameters
  • Optional display of room temperature or setpoint
  • Minimum and maximum setpoint limitation
  • Display temperature in increments of 0.5 °C or °F
  • Color of housing: signal white (RAL 9003)
  • LED backlit display
  • Full or partial keylock
  • Internal sensor calibration
  • Timer with delay off function: preset or user selection from 1 to 23 hours
  • Return to previous mode or Protection (Off) mode upon power down
  • Fan speed low or off in deadzone
  • Fan minimum On-time
  • Three standard color housings on bulk pack for project delivery
  • Customization is also available by request

Additional info

  • LED backlit display
  • Keylock function
  • Display either room temperature or setpoint
  • Comfort and Protection(Off) operating modes
  • Automatic or manual heating/cooling changeover
  • Automatic or manual 3-speed fan control
  • Selectable fan operation in deadzone
  • Timer with delay Off function: preset or user selection from 1 to 23 hours
  • Minimum and maximum setpoint limitation
  • Return to previous operating mode or Protection(Off) upon power down
  • Internal sensor calibration
  • Adjustable commissioning and control parameters
  • Fit into 86x86 conduit boxes
  • Housing available in different colors

 

Technical Specifications:

Operating voltage AC 230 V
Power consumption 12 VA
Setpoint setting range
5…40 °C
Switching differential Heating/Cooling: 0.5…6 K; (factory seeting:1 K);
Relay outputs Fan: Normally open contact , Valve: Normally open contact , Non floating
Relay outputs, number 4
Relay output, switching voltage 230 V
Relay output, switching current 4 (2) A
Type of fixing
Recessed rectangular conduit box BS4662 with fixing centres of 60.3 mm
Dimensions (W x H x D)
86 x 86 x 39 mm

 

Data Sheet

Installation Instruction

View full details